you are here: home page :: circuit diagrams :: Power supplies and high voltage :: The Output Adjustable Flyback Converter
The Output Adjustable Flyback ConverterDescription: Specification: Design Guidelines: The input RMS current in worse condition with discontinuous current mode may be calculated as: If the optimum operating duty cycle is set at D=0.35, then input peak current can be found as: Therefore the voltage sensing limit voltage level from the FAN7554 data sheet is 1.5V author: Simon Oh e-mail: Simon@SoftSwitching.com web site: http://www.zen22142.zen.co.uk |
|
|
|---|