you are here: home page :: circuit diagrams :: Power supplies and high voltage :: Variable Power Supply Using Fixed Regulator
Variable Power Supply Using Fixed RegulatorDescription: Parts List: Notes: The transformer has a 240V primary and has a secondary rated 24V at 2A. The bridge rectifier contains 4 diodes, their current rating needs to be high with respect to the transformers output current; if not the current may damage the diodes. I used MR751 which is rated 6 amps, but another good choice is 1N5400. C1 is the mainfiltering capacitor, the supply is further smoothed by the combination of L1 and C3. C2 and C4 are decoupling capacitors; their action further reduce ripple factor. The regulator, U1 utilizes the action of zener diode ZD1 which is in parallel with the potentiometer, R1. The tuning action of R1 produces a variable regulator output. The output voltage is variable from the regulator output to the regulator output plus the zener voltage. E.G. A 7805 regulator and 10V zener give an output adjustable from 5 to 15 Volts. The regulator may be changed to provide different output voltages as may the zener. the zener should be rated a minimum of 1.3 Watts. All the parts should be available at local electronic shops. Formula for calculating Ripple Factor in Filters: Where: author: David Kwaku Celestin - Ghana, West Africa e-mail: mightycelestin@yahoo.co.uk web site: http://www.zen22142.zen.co.uk |
|
|
|---|